Constant-volume calorimetry
The narrator states the calorimeter heat capacity as 3.3775 kJ/degreeC, but 6.199 kJ divided by 1.642 degreeC is 3.775 kJ/degreeC, and the later caffeine calculation correctly uses 3.775. The 3.3775 value is a stated-number slip; the intervention uses the correct 3.78 kJ/degreeC.
The check-ins use the correct version. The video is Khan Academy's, unchanged.About this video
This video explains constant-volume (bomb) calorimetry. Because the rigid walls allow no work, the heat measured equals the change in internal energy (Delta E), unlike constant-pressure calorimetry where heat equals Delta H. It finds the calorimeter's heat capacity by combusting benzoic acid, then uses it to calculate the heat of combustion of caffeine in kilojoules per mole.
You'll be able to
- describe how a bomb calorimeter works and why its volume is constant.
- explain why heat at constant volume equals Delta E, not Delta H.
- calculate a calorimeter's heat capacity from a known combustion.
- use the calorimeter constant to find a substance's heat of combustion.
Key words
- bomb calorimeter
- A constant-volume calorimeter with rigid walls used to measure combustion heat.
- internal energy (Delta E)
- The energy change measured when heat is transferred at constant volume (no work done).
- heat capacity of the calorimeter (C_cal)
- The heat needed to raise the calorimeter's temperature by one degree, found from a known combustion.
- first law of thermodynamics
- Delta E = q + w, relating internal energy change to heat and work.
Transcript
- [Instructor] Calorimetry refers to the measurement of heat flow. And there are many different types of calorimeters. In this case, we're looking at a constant volume calorimeter which is also called a bomb calorimeter. Let's look at how a bomb calorimeter works.
First, the sample to be combusted is placed in a container that has some oxygen. And then there's some ignition wires that go into this little container here, and the sample is ignited and heat is given off by the combustion reaction. So heat is being transferred from our sample to the water in our containers.
Let me go ahead and draw some water in here. So imagine we have some water, and it's important to know that the container is rigid. So the walls are very, very solid and cannot move. There's also something to stir the water and since heat is being transferred from the combustion reaction to the water, the temperature of the water will increase which we can see on the thermometer.
Now that we understand how a bomb calorimeter works, let's think about that heat that's being transferred from the combustion reaction to the water, so that heat is q. Let's go back to the first law of thermodynamics, which says that the change in the internal energy of the system is equal to q plus w, where q is the heat that's transferred and w is the work done.
Let's say we do this combustion reaction in a container with a movable piston. And the combustion reaction is performed under the constant pressure of the atmosphere. So this time, when we do the combustion reaction, we will transfer some heat. So heat is being transferred from the combustion reaction and we would also produce some gases, which would push up on the piston and so the piston would move up, and since the piston's moving, work is being done by the combustion reaction.
In this case, the heat that's transferred q is done under constant pressure, and so we can write qp here and by definition, the heat that's transferred at constant pressure, that's the change in the enthalpy delta H. So for this example with the container with the movable piston, when we did our combustion reaction, the heat that's transferred at constant pressure is equal to the enthalpy delta H, the change in enthalpy delta H, and as the gases expand and pushing the piston work is done.
Let's compare the example with the movable piston to our bomb calorimeter. Our bomb calorimeter has rigid walls and therefore no work can be done. So the work done is equal to zero. When we plugged that into the first law of thermodynamics, we find that the change in the internal energy delta E is equal to the heat transferred q.
And since this is a constant volume calorimeter right, the walls are rigid. We can write q sub v here. So this heat that's transferred from our combustion reaction in this case is not equal to the change in the enthalpy. It's equal to the change in the internal energy delta E.
So the heat that's transferred at constant pressure is equal to the change in the enthalpy delta H, while the heat that's transferred at constant volume is equal to the change in the internal energy delta E. To do a constant volume calorimetry problem, we need to know the heat capacity of the calorimeter which is symbolized by C with a subscript cal.
To find the heat capacity of the calorimeter, we need to combust something that we know the exact amount of heat for them. For example, if you combust exactly one gram of benzoic acid, you'll get 26.38 kilojoules released of energy. So let's say we have a 0.2350 gram sample of benzoic acid.
And we put that in our calorimeter and we go ahead and combust the benzoic acid. And we find that the temperature increases by positive 1.642 degrees Celsius. To find the heat capacity for the calorimeter, first we take our known amount which is 26.38 kilojoules per gram and we multiply that by how much benzoic acid we used in our calorimeter which was 0.2350 grams.
And so the grams will cancel out and this is equal to 6.199 kilojoules. Next we divide this by our temperature change which was positive 1.642 degrees Celsius. And this gives us the heat capacity of our calorimeter, which turns out to be 3.3775 kilojoules per degree Celsius.
Now that we know the heat capacity for our specific calorimeter, we can use this value to calculate the heat of combustion for another substance. So the heat of combustion for another substance or just q would be equal to the negative of the heat capacity of the calorimeter times the change in the temperature of the water in that calorimeter.
Let's say our goal is to calculate the heat of combustion of caffeine in kilojoules per mole. So we take 0.265 grams of caffeine. We put that in our calorimeter, we combust it and we find the temperature of the water increases by positive 1.525 degrees Celsius.
So to calculate q, q is equal to the negative of the heat capacity of the calorimeter, which is 3.775 kilojoules per degree Celsius. And we multiply that by the temperature change which has 1.525 degrees Celsius. So degrees Celsius cancels out and this gives us negative 5.757 kilojoules.
And technically this is the heat transfer to a constant volume so we could even write q sub v in here, and remember this is equal to the change in the internal energy of our system. So this is qv is equal to delta E. Since our goal is to find the heat of combustion of caffeine in kilojoules per mole, next we need to take our grams of caffeine, which is 0.265 grams, and divide that by the molar mass of caffeine.
And so grams will cancel out and give us moles of caffeine. So this calculation is equal to 1.36 times 10 to the negative third moles of caffeine. Now, all we have to do is divide our heat, which is negative 5.757 kilojoules by our moles of 1.36 times 10 to the negative third moles, to give us a final value of negative 4.23 times 10 to the third kilojoules per mole with a negative sign, meaning heat is given off.
So we can say that this is the value, this is the change in the internal energy for our reaction in kilojoules per mole. And often the change in enthalpy is about the same as the change in the internal energy. So we can say that this is approximately equal to the change in the enthalpy for the reaction as well.
Video © Khan Academy, used under CC BY-NC-SA. Watch on Khan Academy. Puzzicle is not affiliated with Khan Academy.